How To Tell When A Structure Is Not Professionally Done

How to tell when a structure is not professionally done.

This house had a very large addition added to the back.  The addition is supported by foundation walls on the exterior perimeter of the room, with two double Micro-laminate beams across the span.  Under the entire addition is a crawl space.

When so many things are not done properly, one begins to expect that what looks proper may not be!

The wood beams enter the foundation walls like this one.  ALL FOUR LOOKED LIKE THIS ONE.

There should be a space all around where the wood does not touch the concrete (or mortar).

The bottom seems supported by what looks like a wood-splitting wedge to me.  These are driven into the end of logs with a sledge hammer to split the log.  It is NOT designed to be a shim in any way.

And you can see how tightly it is held in place!  Now that's a secure structure!

Engineering codes say this double beam should extend 3" into the wall onto a shelf called a "corbel."  Certainly I could not tell if this was so. 

Given what is elsewhere I would wonder.

The double beams should be secured to each other with through bolts.

The supportive columns should  each be through bolted to the beams.  None is.

This column is not attached in any way.

This column is too small.

This column is not centered.

This column is not plumb.

This column is supposed to sink 24" into the ground and rest on a concrete footer.

Does it?

Given what is elsewhere I would wonder.

The room above has a hardwood floor that is not level, but has gentle rises and falls throughout the room.  That would be related to this structure below.

In the attempt to solve this problem various makeshift columns were put into place.

Many look like this one, resting on a board that is itself resting on the ground.

You can see another type of makeshift column to the right.

Above it is not attached to the joist it is "supporting."

But it is resting directly on the ground and not even on a board so it is sinking.

There are other things, but this is enough to give the idea as to the erratic nature of the floor of this  room.  Professional?

Was this work done with a permit?  Was the permit closed?  Was this structure approved for occupancy?

Given what is elsewhere I would wonder.

My recommendation:  it took quite a while to crawl around and see what there was to see.  It was not easy!  This photo shows what a lot of the crawl space looked like!  It is important that a home inspector look carefully at areas like this crawl space.  It's a part of the job.  And it's a good thing this home inspector decided to go in despite all the boards that had nails in them and the rest of the junk in the space. 

 

 

 

Jay Markanich Real Estate Inspections, LLC  

Based in Bristow, serving all of Northern Virginia.

Office (703) 330-6388   Cell (703) 585-7560

www.jaymarinspect.com


Comment balloon 13 commentsJay Markanich • June 29 2016 04:37AM
How To Tell When A Structure Is Not Professionally Done
share
How to tell when a structure is not professionally done. This house had a very large addition added to the back. The addition is supported by foundation walls on the exterior perimeter of the room, with two double Micro-laminate beams across the… more
"The Loft Room Is Always Warm - It Won't Cool, No Matter What…
share
During the phone call I heard, "The loft room is always warm - it won't cool, no matter what. " They understood I have the ability to "see" insulation. While that is not exactly true, Mighty Mo has the ability to distinguish warm… more
A Pre-Drywall Inspection Is The Only Time To See This
share
A pre-drywall inspection is the only time to see this. A thermal camera can show where areas are not insulated or not insulated well. But why find that out after the house is built? A pre-drywall inspection is the only time to see the house in a… more
The Entry Way Chandelier Had Been Replaced With This
share
Walking through the house my clients found that the entry way chandelier had been replaced with this. It is not unusual for an appliance or light fixture to have a note on it that says it will be replaced with something else. It might have been a… more
A Garage Wall Is Still An Exterior Wall
share
A garage wall is still an exterior wall. And, as such, if it abuts the house, it needs to be insulated! Remember the 5% Rule! On a new construction inspection I noticed something interesting. The room adjoining the kitchen and garage was very warm… more
This Is An Electrical "Repair" You Will Not Believe
share
This is an electrical "repair" you will not believe. This is so disheartening. What good is a license in a trade if it is demonstrated over and over that it means nothing? In recent years my problem with the trades is the absolute… more
Sneaky, Just Not Sneaky Enough
share
Sneaky, just not sneaky enough. Some sellers who move out of the house and have it painted and nice leave the place looking nice. And some sellers do things to try to hide problems that are being pushed off onto someone else. When I see sneaky in… more
Improper Attic Access Ladder Installation
share
I see it all the time, on new construction and old - improper attic access ladder installation. Attic access ladders span the distance between ceiling and floor. That distance can vary - 8, 9, 10, and even more feet. Attic access ladders have to… more
Danger - Rust In Electrical Panel Box Components
share
Danger - rust in electrical panel box components. The percentage of the time would be unknown, but I often see rust in panel box components. There is debate surrounding how much is too much. To me there cannot be much debate or room for error… more
When The Cable Guy Shovels The Snow In The Attic
share
This is what you get when the cable guy shovels the snow in the attic. On new construction it is best to get subs to do things in proper order. What if the cable guy is scheduled to show up AFTER the insulation is blown into the attic space? Gee… more